Maquet servo i cleaning manual

Our commitment is to continue to earn your business with hard work and dedication. Maquet servo ventilators set the standard for the field of critical care. Expiratory cassette, servou 66 93 752 one expiratory cassette is delivered with each base unit. Servo s service manual power supply personal computers. The servo i servo s computer interface emulator is an integrated part of the servo i servo s. Maquet servo i adult model ventilator teaching unit. The servoi is cleaned according to instructions in the users manual, chapter routine cleaning and chapter regular maintenance, section extended cleaning of inspiratory channel. Highlevel disinfection of respiratory equipment takes place after cleaning, and is typically accomplished by chemical germicides or physical methods, as outlined below. Date hs code description origin country port of discharge unit quantity value inr per unit inr sep 28 2016. Ventilation servoi, servos, servoun and compressor. The servo i ventilator system must be serviced at regular intervals by maquet authorized personnel who have received specialized training. Apr 14, 2016 maquet servo i ventilator pre use check duration. A onepiece interchangeable expiratory cassette means the system can instantly be made ready for the next patient.

Maquet servo i user manual maquet servo i user manual servo u. It has full monitoring capabilities and delivers ventilation down to a depth of 30 meters. Maquet getinge group k123149 servo i and servo s 510k summary prepared in accordance with 21 cfr part 807. The installation and handingover procedures are described in the servoi ventilator system installation instructions. Installation only personnel trained and authorized by maquet shall be permitted to install the servo i. Flow pattern the flow pattern in volume control and simv vc is constant during inspiration. Maquet recommends the use of servo duo guard bacterial filter or. Contributes to ensure a controlled and certified transfer of software via the mcc. Maquet is committed to continuous development of the platform. Important servo i ventilator system revision 02 service manual 1 7 articles of consumption 1. Service and operator manual of maquet servo i universal december 14, 2010 09. Enhanced interaction offers unprecedented levels of speed in sensing and control.

Maquet recommends that a bacterialviral filter is always connected to the. We service more ltvs than any other service center in the country and stock the largest inventory of spare parts, so we can execute the fastest turnaround of pms and repairs in the country. Service and operator manual of maquet servoi universal. Maquet critical care ab servo i, back to search results is a peep high alarm positive end expiratory pressure higher. With manual cleaning, the two essential components are friction and fluidics. Servo s represents servo s ventilator system of system version 5.

Based on proven servo technology, servo s offers leading edge mechanical ventilation in a straightforward package. Edelivery upgrade via edelivery, servo i 66 50 100 neccessary for edelivery of software option upgrades via the mcc sw download website maquet. Maquet datascope cs300 service manual pdf download. Optimizing your equipments services is often an untapped opportunity to maximize. The servos ventilator is based on proven servo technology, ensuring safe, reliable and high quality ventilation. Operators manual pdf download servo i brochure pdf download. Right now, the servo is being used the same way as the avea we just need to get used to the new nomenclature, buttons, sounds, etc. The intuitive icu ventilator that inspires confidence and provides our evh systems accelerate recovery and meet the needs of clinical users at all. H led customer technical manual en 0160301 1d 3 3 contents 1 symbols used in this manual 4 2 quality standards compliance 5 2. It has the ability to handle the most acute phases of respiratory distress, through recovery, and to the waning phases of the ventilation process. The servo s is also designed for easy cleaning and maintenance. Maquet servo i combines a high level of clinical performance for invasive, noninvasive or neurally controlled venting with exceptional freedom and cost efficiency. Duo guard bacterial filter or equivalent to reduce the transmission of bacteria from the patient via the expiratory channel to.

Maquet 6688485 5000 hour maintenance kit siemens maquet servo i maintenance kit 6532621. Responsibility for the product was assumed by maquet critical care in 2003. By combining stateoftheart sensitivity and reliability with userfriendly simplicity, servos delivers top performance for both adult and pediatric patients in a variety of hospital ventilatory care settings. Make sure that the servo system works properly before performing any maintenance. Servo i hbo can provide icuquality ventilation in the hyperbaric chamber. The leakage current test is a standard procedure regulated by iec 60 6011 or corresponding national standards. Maquet servoi ventilator featuring infant, adult, and. For cleaning procedures, refer to the servo ventilator system users manual.

Soma technology offers the maquet servo i ventilator up to 50% below oem prices with the same service and warranty as new. The maquet servo i ventilation platform can be used on a variety of patients from neonatal to adult. Servoi ventilator systemservice manual critical care. With power supply connected to the servo i, there are energized electrical components inside the unit. Preventive maintenance access and replacement instructions 5. Siemens servo i ventilator service manual med one capital. Installation only personnel trained and authorized by maquet shall be permitted to install the servoi. Dec 11, 2011 ensure that the software is fully compatible with all hw, sw and mechanical components in the unit.

If a servo duo guard or performance equivalent filter is connected, then it is usually. After unpacking, the ventilator must be checked and, if necessary, calibrated. Thank you in advance for the opportunity to serve you and we look. Designed for shelf or mobile cart mounting for inhospital transport, it incorporates a 12. The servo duo guard is bidirectional and intended to be used on both the expiratory andor inspiratory limbs of breathing circuits. Ventilators plus is dedicated to the highest level of customer service and support. Expiratory cassette, servo u 66 93 752 one expiratory cassette is delivered with each base unit. Maquet servo i ventilator supports both invasive and noninvasive ventilation. Maquet critical care ab rbngenvagen 2 se171 54 solna, sweden tel. Warnings, precautions and notes please read and adhere to the following list of warnings, precautions and notes. The unit is cleaned according to instructions in the users manual, chapter routine cleaning a n d c h a p t e r maintenance, section extended. Manufacturing of the product was discontinued in 2004. The servo i continuously delivers ventilator therapy that is outstanding.

Maquet servoi a wealth of features and functionalities for treating adult. Maquetservoiservicemanual med one capital mafiadoc. The maquet siemens servo i was the first ventilator on the market engineered to evolve with medical professionals changing needs. Bender safety tester 601751 or equivalent is recommended. The servo ventilator 900 was orginally manufactured and sold by siemens. Maquet recommends methods that havebeen validated using the specified equipmentand procedures outlined in this manual. Servo i service seminar is a 2 day course covering the operation, maintenance and repair of the servo ventilation system. Allowable values and test methods are defined in the standard. Maquet servoi community, manuals and specifications. Cleaning procedure of expiratory cassette nisam biomedical. The servo s, by maquet getinge, based on servo technology, is a device that offers mechanical ventilation for adult and pediatric patients. The servo s ventilators simplicity of use makes it easier to provide high quality ventilation bedside, giving you more time to focus on patient care.

Thus, some information in the service manual may be outdated. Covid ventilate multiple patients with one ventilator with different pressurevolume and peep duration. The installation and handingover procedures are described in the servo i ventilator system installation instructions. Servois cleaning and maintenance users manual rev 00 oct. It must be operated according to the instructions in this operating manual. Servo i delivers a high level of clinical performance for a variety of situations and for all patients. Neurally adjusted ventilatory assist nava nava is a unique approach to mechanical ventilation as it listens to the patients own respiratory signal. This helps clinicians provide costeffective care throughout the hospital. We have 1 maquet datascope cs300 manual available for free pdf download. Software automode, servou 66 93 655 automode pc ps. Since 2001 maquet has released new functionality for the siemens servo i on a yearly basis with 100% backwards compatibility.

Right now, the servo is being used the same way as the avea. Maquet servo sservos immediately responds to patient needs in terms of pressure and flow changes in a variety of modes. Lab sessions will provide an opportunity for hands on training in system operation, calibration, function check and troubleshooting of the system. Take a tour with george as he describes the external features of the maquet servo i mechanical ventilator. The servos ventilators simplicity of use makes it easier to provide high quality ventilation bedside, giving you more time to focus on patient care. Service technicians forum service and operator manual of maquet servo i universal anas ibraheem gulfmedical co. Users manual ventilation servois cleaning and maintenance table of. The maquet servo i ventilation system can be used on a variety of patients from neonatal, pediatric, to adults. All are easy to understand, implement and use, making it simple to integrate advanced personalized ventilation strategies into your daily patient care. For detailed information please always refer to the latest corresponding users manual andor instructions for use. This philosophy secures lasting value for your investment.

Preparations make sure that the servo system is properly cleaned before performing any maintenance. Servo ventilator 900 c must be operated only by authorized personnel who are well trained in its use. All data on pressures for servo ventilator 900 c are given in cm h 2 o. Manuale duso maquet servo ventilator 900 c il respiratore. Manual breath it initiates an additional breath o2 breaths instantly changes fio2 to 100% does not allow you to set a 1020% increase as the avea.

The information in this reference manual is valid for both the servo i v5. It has the power to handle the phases of distress into the waning stages of the ventilation procedure and through retrieval. A wealth of features and functionalities for treating adult, pediatric and neonatal patients. These new tools have the potential to make a significant difference in terms of. The servos, by maquetgetinge, based on servo technology, is a device that offers mechanical ventilation for adult and pediatric patients. Jul 28, 2017 cleaning procedure of maquet ventilator expiratory cassette. The servoi is cleaned according to instructions in the users manual, chapter. Users manual servo i shelf base installation instructions support arm 177 servo i. Maquet servos community, manuals and specifications. Based on proven servo technology, servos offers leading edge mechanical ventilation in a straightforward package. Check that a servo ventilator system users manual and a. Please note that this service manual has only been relabeled from siemens to maquet.

Jul 23, 20 h led customer technical manual en 0160301 1d 3 3 contents 1 symbols used in this manual 4 2 quality standards compliance 5 2. Cleaning procedure of maquet ventilator expiratory cassette. Covid ventilate multiple patients with one ventilator with different pressurevolume and peep. M 5 500 f i care important servo s ventilator system notes 1 2 service manual revision 01 contents servo s ventilator system contents 1 1 important 2 introduction 3 description of functions 4 disassembling and assembling 5 service procedures 6 troubleshooting 7 preventive maintenance. With power supply connected to the servoi, there are energized electrical components inside the unit. It comprises all of the modes you would expect from an innovative ventilation system in the platform. Ventilation servoi, servos, servoun and compressor mini. All maquet servo i ventilatory configurations are effective for bedside use and the majority of them are also accessible mr and hbo editions.

Manuals and user guides for maquet datascope cs300. Servo u gives you many options for personalized lung protection and weaning. Vacuum the input and the inside of the front panel, and the input of the power. The servo i is cleaned according to instructions in the users manual, chapter routine cleaning and chapter regular maintenance, section extended cleaning of inspiratory channel. Foreword introduction foreword this manual is intended to provide information required to properly service the datascope cs300 intraaortic balloon pump.

1321 1493 1282 465 694 1066 459 795 1282 374 609 41 1174 514 643 182 651 940 692 1025 1511 317 1001 916 1527 538 1132 1185 1461 544 850 1531 517 576 817 1229 1188 800 583 1498 997 1455